Varachha Road, Surat, Gujarat
GST No. 24BJYPV8517P1ZV
Call 07942821961 95% Response Rate
Send Enquiry
Minimum Order Quantity: 1 Piece
Product Brochure
| Screen Size | 12.1 Inch |
| Display Type | LCD |
| Model Name/ Number | BPL Vivid Vue 12i |
| Dimensions (L x W x H) | 345mmx181mmx292mm |
| CNS Back panel connector (Optional) | Yes |
| Operating Relative Humidity | 15% to 85% |
| Optional Connectivity | HL7 with HIS connectivity, USB for patient data output, DVI for external (Slave) display, Nurse call |
| Body Material | Plastic |
| Country of Origin | Made in India |
Features
| Specification | Details |
|---|---|
| Display | Vivid Vue 12: 12.1″ (Optional Touch Screen) |
| Resolution | Pixel: 800×600 pixels |
| Display Information | 7 waveforms display / 12- Lead ECG interface |
| Dimension | Vivid Vue 12: 345mm×181mm×292mm |
| Weight | Vivid Vue 12: < 3.6kg |
| Built-in Battery | Rechargeable Lithium-ion battery, 14.8V/2600mAH; ≥ 3.5 hrs of backup |
| Battery Charge Time | ≤ 3.5 hours |
| Specification | Details |
|---|---|
| Lead Mode | Standard: 5 lead Optional: 12 lead & 3 lead |
| Heart Rate Range & Accuracy | 10–300 bpm; Accuracy: ±1% or ±1 bpm, whichever is greater |
| Gain | 2.5 mm/mV (×0.25), 5 mm/mV (×0.5), 10 mm/mV (×1), 20 mm/mV (×2) |
| Sweep Speed | 12.5 mm/s, 25 mm/s, 50 mm/s |
| ST-Segment | Detection Range -2.0mV to +2.0mV |
| Respiration Method | Thoracic impedance |
| RR Measurement Range & Accuracy | 1–150 breaths per minute; Accuracy: ±2 bpm |
| Delay of Apnea | 10s, 15s, 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s |
| Specification | Details |
|---|---|
| Measurement Method | Automatic oscillometry |
| Systolic Range | ADULT: 40–260 mmHg PEDIATRIC: 40–230 mmHg NEONATE: 40–130 mmHg |
| MAP Range | ADULT: 20–220 mmHg PEDIATRIC: 26–183 mmHg NEONATE: 26–110 mmHg |
| Diastolic Range | ADULT: 20–200 mmHg PEDIATRIC: 20–160 mmHg NEONATE: 20–100 mmHg |
| Pressure Transducer Accuracy | ±3 mmHg between 0 mmHg – 300 mmHg (0°C–50°C) |
| Auto Measurement Interval | 1min, 2min, 3min, 4min, 5min, 10min, 15min, 30min, 60min, 120min, 240min, 480min, 960min |
| STAT Mode | Yes |
| Specification | Details |
|---|---|
| BPL Oxy Sat+ SPO2 | Range: 0%-100%; Accuracy: ±2% (70-100%); 0%-69% not defined |
| PR Measurement | 25–250 pulses/min |
| Masimo SPO2 | Range: 1%-100%; Accuracy: ±2% (adult/child); ±3% (neonate); within 70%-100%, 0%-69% not defined |
| PR Measurement | 25–240 pulses/min |
| Brand | PI Resolution |
|---|---|
| BPL Oxy Sat+ | 0.06%–20%; Accuracy not defined; Resolution: 0.01% |
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Screen Size | 12.1 Inch |
| Display Type | LCD |
| Model Name/ Number | Ultima Prime D |
| Dimensions (L x W x H) | 318 x 264 x 152 mm |
| CNS Back panel connector (Optional) | Yes |
| AC Mains Variation | Standard Configuration: ECG, RESP, Nellcor SpO2 / Masimo SpO2/ Digital SpO2, NiBP, TEMP |
| Operating Relative Humidity | Optional Parameters & Configuration: Dual IBP, ETCO2, AGM, ICG, Thermal recorder |
| Optional Connectivity | Can display upto 10 waveforms |
| Body Material | Drug dose calculation, HRV analysis & Hemodynamic calculation |
| Country of Origin | Made in India |
| ECG Cable |
| SpO2 Sensor |
| NIBP Cuff (Adult) with cable |
| Temperature Sensor |
| Power Cable |
| User Manual |
Additional Information:
View Complete details