| Channels | 3 Channel |
| Usage Type | Portable ECG |
| Display Type | Touchscreen LCD |
| Model Name/No. | VD-300E |
| Type | Digital |
| Recording Type | Thermal Printing |
| Paper Width | 80 mm |
| Power Source | Rechargeable Battery |
| Machine Type | Digital |
| Recording Speed | 25, 50mm/s +3% |
| Operating Mode | Automatic |
| Battery Operating Time | 2.5 Hour |
| Weight | 4 Kg |
| Rechargable Battery | Yes |
| Ecg Lead Annotation | Yes |
| Interpretation | With Interpretation |
| Built In Printer | Yes |
| Warranty | 1 Year |
| Accessories | Patient Cable, Power Cord, User Manual And Warranty Card |
| Number Of Channels | 3 Channels |
| Iso Certification | Yes |
| Visual Alarm | Yes |
| Digital Thermal Array Printer | Yes |
| Standard Thermal Paper | Yes |
| Carry Handle | Yes |
| Model Name/Number | VD-300E |
| Brand | VD Bio Medisystems |
General Features
· 12 Lead ECG Synchronous Sampling System
· Thermal Printer With 80mm Print Paper, Synchronization Print
· 5.7" Colour Touch-Screen, Both Push-Button and Touch Operation
· Automatic Measurement, Calculation, Analysis, Waveform Freezing
· Support USB Flash Disk & SD Memory
· Data Transmitting to PC via RS232/USB
· Patient's Information can be Input
· Historical Data can be Reviewed and Printed
· Built-in Rechargeable Lithium-ion Battery, AC/DC Power Conversion
· Sleep Mode to Save Energy and Extend LCD Life
· Portable Design with Hidden Handle, Convenient to Carry
· Lead Off & Lack Off Paper Detection Function
7 Level Printing Thickness AdjustableTechnical Specification
· Input Mode: Floating and Defibrillation Protection
· Voltage Tolerance: +500mV
· Frequency Response: 0.05Hz ~ 150Hz (-3dB~+0.4dB)
· CMRR: ≥100dB (With AC filter) | | Time Constant: ≥ 3.2s
· Patient Leak Current: <10 A | | Calibration Voltage: 1mV +3%
· Sensitivity: 5, 10, 20 mm/mV +5%, Standard Sensitivity: 10mm/mV +2%
· Noise Level: <15uVp-p || Input Circuit Current: ≤ 0.1 uA
· Input Impedance: ≥50M Resolution: 12-bit/1000Hz
· Recording Mode: High Resolution Thermal Printing System
· • Auto Record: Set Record According to Auto Record Format and Mode, Auto Switching Leads, Measuring and Analysing
· Manual Record: Set Record According to Record Format, Manually Switching Leads
· Filter: AC, ECG Filter | | Drift Filter: Anti-Drift System
· Paper Speed Auto: 25, 50mm/s +3%
· Power Supply AC: 100V ~ 240V(50/60Hz), DC: 11.1V/3800mAh Rechargeable Lithium Battery
· Fuse Specification: AC Time Lag Fuse (O5×20mm), T1.6AL 250V
· Dimension: 360mm x 250mm x 68mm
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Usage Type | Resting ECG |
| Type | Portable |
| Number Of Channels | 6 Channels |
| Display Type | Touchscreen LCD |
| Recording Type | Thermal Printing |
| Paper Width | 112 mm |
| Lead Type | 12 Lead |
| Power Source | Rechargeable Battery |
| Machine Type | Digital |
| Model Name/Number | CMS600G |
| Storage Inbuilt Memory | YES |
| Packaging Type | Box |
| Usage/Application | Hospital |
| Weight | 4 kg |
| Rechargable Battery | Yes |
| Ecg Lead Annotation | Yes |
| Sensitivity | 5 |
| Connectivity | LAN |
| Built In Printer | Yes |
| Interpretation | With Interpretation |
| Accessories | User Manual And Warranty Card, Patient Cable, Power Cord |
| Warranty | 1 Year |
| Brand | Contec |
| Country of Origin | Made in India |
Performance
Input mode: floating and defibrillation protection
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
CMRR: >60dB, >100dB(add filter)
Time constant:≥ 3.2s
Patient leak current: <10µA
Calibration voltage: 1mV
Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
Noise level: <15µVp-p
Input circuit current: ≤50nA
Input impedance: ≥50MΩ
Sampling accuracy: 12-bit
Safety classification: class I, type CF and defibrillation-proof applied part
Recording mode: thermal printing system
Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.
Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.
Manual record: set record according to record format, manually switching leads.
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Paper size: 110mm(W)×20m(L)
Sampling frequency: 1000Hz
EMG interference filter: 25Hz/35Hz (-3dB)
Power frequency filter: AC 50Hz/60Hz(-20dB)
Paper speed:
Auto: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%
Rhythm: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%
Manual: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%
Accessories
Standard:
A lead cable
A limb electrode
A chest electrode
A thermal recording paper
A power cord
An earth wire
A user manual (GB only)on request for other Language
Physical characteristic
Dimension: 315mm(L) × 215mm(W) × 92mm(H)
Weigh: 1.7Kg
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Usage Type | Resting ECG |
| Type | Portable |
| Number Of Channels | 6 Channels |
| Display Type | Touchscreen LCD |
| Recording Type | Thermal Printing |
| Paper Width | 112 mm |
| Lead Type | 12 Lead |
| Power Source | Rechargeable Battery |
| Machine Type | Portable |
| Storage Inbuilt Memory | Yes |
| Model Name/Number | CMS-600G |
| Packaging Type | Box |
| Usage/Application | Clinic |
| Ecg Lead Annotation | Yes |
| Weight | 3.5 KG |
| Rechargable Battery | Yes |
| Sensitivity | 5 |
| Connectivity | LAN |
| Interpretation | With Interpretation |
| Built In Printer | Yes |
| Warranty | 1 Year |
| Accessories | Power Cord, User Manual And Warranty Card, Patient Cable |
| Iso Certification | Yes |
| Standard Thermal Paper | Yes |
| Carry Handle | Yes |
| Brand | Contec |
| Country of Origin | Made in India |
Introduction
ECG600G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, case database management.
Function
1)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.
2)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).
3)Full-digital filter design, anti-baseline drift, AC and EMG interference.
4)Adjust the baseline automatically, optimize the print setting and optional rhythm leads.
5)In AUTO mode, finish recording by pressing the button once, which improves work efficiency.
6)Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
7)With the functions of auto-measurement, auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctor’s burden and improves work efficiency.
8)Sync collection for 12-lead ECG, multiply printing formats, including 2×6+1(rhythm lead), 2×6, 3×4, 3×4+1(rhythm lead), 4×3, 4×3+1(rhythm lead), 6×2, 6×2+1(rhythm lead), rhythm 2, rhythm 3, rhythm 4, rhythm 5, rhythm 6, rhythm 7, channel record, etc.
9)Display of 3/6/12-lead ECG, "Lead off" and "Lack of paper" on one screen, and with ECG DEMO mode. Auto-check and auto-analysis for ECG parameters, ECG waveform can be recorded manually or automatically. And patient information can be stored by case database.
10)Time print can be set to every 1/2/3/5/10/20/30/60 minutes.
Performance
Input mode: floating and defibrillation protection
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
CMRR: >60dB, >100dB(add filter)
Time constant:≥ 3.2s
Patient leak current: <10µA
Calibration voltage: 1mV
Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
Noise level: <15µVp-p
Input circuit current: ≤50nA
Input impedance: ≥50MΩ
Sampling accuracy: 12-bit
Safety classification: class I, type CF and defibrillation-proof applied part
Recording mode: thermal printing system
Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.
Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.
Manual record: set record according to record format, manually switching leads.
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Paper size: 110mm(W)×20m(L)
Sampling frequency: 1000Hz
EMG interference filter: 25Hz/35Hz (-3dB)
Power frequency filter: AC 50Hz/60Hz(-20dB)
Paper speed:
Auto: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%
Rhythm: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%
Manual: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%
Physical characteristic
Dimension: 315mm(L) × 215mm(W) × 92mm(H)
Weigh: 1.7Kg