Call 07942821961 95% Response Rate

Send Enquiry

our range

Automated External Defibrillator

Pioneers in the industry, we offer aed7000 m&b automated external defibrillator, aed7000 large automated external defibrillator and aed7000 small automated external defibrillator from India.

AED7000 M&B Automated External Defibrillator

  • AED7000 M&B Automated External Defibrillator
  • AED7000 M&B Automated External Defibrillator
  • AED7000 M&B Automated External Defibrillator
  • AED7000 M&B Automated External Defibrillator
  • AED7000 M&B Automated External Defibrillator
  • AED7000 M&B Automated External Defibrillator
  • AED7000 M&B Automated External Defibrillator
  • AED7000 M&B Automated External Defibrillator
  • AED7000 M&B Automated External Defibrillator
AED7000 M&B Automated External Defibrillator
Get Best Quote
Rs 52,500  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

SizeSmall
TypeAutomatic External Defibrillators
BrandM&B
Usage/ApplicationHome & Public Place
Model Name/NumberAED7000
FrequencyUltrasound Frequency - 2.5MHz
Warranty1 Year Warranty
Operation ModeAutomatic
Battery TypeLithium Battery
Country of OriginMade in India
General Features • Three-Step Defibrillation Process • Two-Button Operation • Extensive Voice and Visual Prompts for The Operator • Continuous Event Recording for Reporting Each Use to a Printer or Computer • Weekly Self-Test to Ensure Readiness • Biphasic Energy Out put • Lock-Out Protection to Prevent Inadvertent Defibrillation

Technical Specification
Defibrillator • Output: Biphasic Truncated Exponential • Audible Prompts: 20 Audible Prompts • Energy Sequence: 150, 150, 200 J • Visual Prompts: LED Prompts • Analysis Time: 9 Sec • Controls: Two Buttons- On/Off, Shock • Charge Time: 8 Sec. (150J), 10 Sec. To 200J (New Battery) • The Maximum Voltage: 1200150V • Max Time from The Initiation of Rhythm Analysis to Readiness for Discharge with A New Battery: < 30 Seconds • Max Time from The Initiation of Rhythm Analysis to Readiness for Discharge After 6 Shocks: < 35 Seconds • Maximum Time from The Initiation of Rhythm Analysis to Readiness for Discharge: < 25 Seconds • Output Energy Accuracy: $15% Into Impendence from 25 To 750 • Output Disabled When the Patient Impedance is Outside Limits: 200 to 200 

Additional Information:

  • Item Code: AED7000

View Complete details

Yes! I am Interested Request a call back

AED7000 Large Automated External Defibrillator

  • AED7000 Large Automated External Defibrillator
  • AED7000 Large Automated External Defibrillator
  • AED7000 Large Automated External Defibrillator
  • AED7000 Large Automated External Defibrillator
  • AED7000 Large Automated External Defibrillator
  • AED7000 Large Automated External Defibrillator
  • AED7000 Large Automated External Defibrillator
  • AED7000 Large Automated External Defibrillator
AED7000 Large Automated External Defibrillator
Get Best Quote
Rs 55,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

SizeLarge
TypePublic access
Model Name/NumberAED7000
Frequency50Hz
Warranty1 Year Warranty
Weight3 KG
Dimension303 X 216 X 89 mm

General Features

Three-Step Defibrillation Process

Two-Button Operation

• Extensive Voice and Visual Prompts for The Operator

• Continuous Event Recording for Reporting Each Use to a Printer or Computer

• Weekly Self-Test to Ensure Readiness

Biphasic Energy Output

Lock-Out Protection to Prevent Inadvertent Defibrillation

 

Technical Specification

 Defibrillator

• Output: Biphasic Truncated Exponential

• Audible Prompts: 20 Audible Prompts

• Energy Sequence: 150, 150, 200 J

• Visual Prompts: LED Prompts

• Analysis Time: 9 Sec

• Controls: Two Buttons- On/Off, Shock

• Charge Time: 8 Sec. (150J), 10 Sec. To 200J (New Battery)

• The Maximum Voltage: 1200150V

• Max Time from The Initiation of Rhythm Analysis to Readiness for Discharge with A New Battery: < 30 Seconds

• Max Time from The Initiation of Rhythm Analysis to Readiness for Discharge After 6 Shocks: < 35 Seconds

• Maximum Time from The Initiation of Rhythm Analysis to Readiness for Discharge: < 25 Seconds

• Output Energy Accuracy: +15% Into Impendence from 25 To 750

• Output Disabled When the Patient Impedance is Outside Limits: 200 to 200

 

Physical

• Dimensions: 303 X 216 X 89 mm

• Weight: 2 Kg

• Operating Temperature: 0°C To 40°C

• Operating Humidity: Relative Humidity Between 30% And 95% (Non-Condensing)

• Storge Temperature: -20°C To 55°C (Without Battery)

• Storge Humidity: Up To 93% (Non-Condensing) (Without Battery)

 

Battery

• Part No: CR123A-4X2

• Non-Rechargeable: 12V DC. 3.0 Ah

• Capacity: 100 Discharges at 200 Joules Or 120 Discharges At 150 Joules

• Shelf Life (25°C+15°C): 10 Years (5 Years Storage + 5 Years Standby)

1 Years Standby (After Installation)

View Complete details

Yes! I am Interested Request a call back

AED7000 Small Automated External Defibrillator

  • AED7000 Small Automated External Defibrillator
  • AED7000 Small Automated External Defibrillator
  • AED7000 Small Automated External Defibrillator
  • AED7000 Small Automated External Defibrillator
  • AED7000 Small Automated External Defibrillator
  • AED7000 Small Automated External Defibrillator
  • AED7000 Small Automated External Defibrillator
  • AED7000 Small Automated External Defibrillator
  • AED7000 Small Automated External Defibrillator
  • AED7000 Small Automated External Defibrillator
AED7000 Small Automated External Defibrillator
Get Best Quote
Rs 55,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

SizeSmall
TypePublic access
Model Name/NumberAED7000
Frequency50Hz
Warranty1 Year Warranty
Weight4 KG
Dimension303 X 216 X 89 mm

General Features

Three-Step Defibrillation Process

Two-Button Operation

• Extensive Voice and Visual Prompts for The Operator

• Continuous Event Recording for Reporting Each Use to a Printer or Computer

• Weekly Self-Test to Ensure Readiness

Biphasic Energy Output

Lock-Out Protection to Prevent Inadvertent Defibrillation

 

Technical Specification

 Defibrillator

• Output: Biphasic Truncated Exponential

• Audible Prompts: 20 Audible Prompts

• Energy Sequence: 150, 150, 200 J

• Visual Prompts: LED Prompts

• Analysis Time: 9 Sec

• Controls: Two Buttons- On/Off, Shock

• Charge Time: 8 Sec. (150J), 10 Sec. To 200J (New Battery)

• The Maximum Voltage: 1200150V

• Max Time from The Initiation of Rhythm Analysis to Readiness for Discharge with A New Battery: < 30 Seconds

• Max Time from The Initiation of Rhythm Analysis to Readiness for Discharge After 6 Shocks: < 35 Seconds

• Maximum Time from The Initiation of Rhythm Analysis to Readiness for Discharge: < 25 Seconds

• Output Energy Accuracy: +15% Into Impendence from 25 To 750

• Output Disabled When the Patient Impedance is Outside Limits: 200 to 200

 

Physical

• Dimensions: 303 X 216 X 89 mm

• Weight: 2 Kg

• Operating Temperature: 0°C To 40°C

• Operating Humidity: Relative Humidity Between 30% And 95% (Non-Condensing)

• Storge Temperature: -20°C To 55°C (Without Battery)

• Storge Humidity: Up To 93% (Non-Condensing) (Without Battery)

 

Battery

• Part No: CR123A-4X2

• Non-Rechargeable: 12V DC. 3.0 Ah

• Capacity: 100 Discharges at 200 Joules Or 120 Discharges At 150 Joules

• Shelf Life (25°C+15°C): 10 Years (5 Years Storage + 5 Years Standby)

1 Years Standby (After Installation)

View Complete details

Yes! I am Interested Request a call back

EXPLORE MORE CATEGORIES